====== First Alert (aka BRK Brands, Inc.) ====== ===== Smoke & Fire Alarm (ZSMOKE) ===== To include this device: - Put your Z-Wave interface into inclusion mode - Slide out the battery compartment on the smoke alarm - Press and hold the Test/Silence button while sliding the battery compartment back in - Release the button - your interface should show a successful inclusion The device will stay awake for 30 seconds so if you're doing a resync you'll want to be pretty quick. Exclusion works the same way, just make sure you have your interface in exclusion mode in step 1 above. When the alarm detects smoke/fire, the device state for the Indigo device will turn ON. When the alarm stops detecting smoke/fire the device state will go OFF. Pressing and holding the Test/Silence button will start a test - the device will go on and sound 3 beeps twice. After the second set of beeps, the alarm will stop sounding and the device will go off in Indigo. We've enabled the Turn On/Off buttons in the control area so you can manually adjust the on/off state if it gets out of sync. It will not effect the actual operation of the alarm. [[http://www.indigodomo.com/devices/216/|Device Information]] [[https://forums.indigodomo.com/viewtopic.php?f=46&t=10838|Discuss this device]] ===== Smoke/Fire & Carbon Monoxide Alarm (ZCOMBO) ===== This device is basically identical to the ZSMOKE except it will also alarm on high Carbon Monoxide readings. Indigo won't know which caused the alarm to sound - it's just a single ON/OFF command. Inclusion information is the same as above. [[http://www.indigodomo.com/devices/217/|Device Information]] [[https://forums.indigodomo.com/viewtopic.php?f=46&t=10838|Discuss this device]] (same topic as the ZSMOKE)