| + | ====== Insteon Locks and Lock Controllers ====== | ||
| + | Currently, Insteon only supplies a single lock controller. | ||
| + | |||
| + | ===== MorningLinc ===== | ||
| + | |||
| + | The MorningLinc controller uses RF to control locks and deadbolts from Morning Industries. Because the RF communication is one-way, there is no status presented from the lock to the MorningLinc, | ||
| + | |||
| + | The controller has an additional Insteon security feature which requires special linking steps. Specifically, | ||
| + | |||
| + | To define the MorningLinc device in Indigo for the Locked (Turn On) Command: | ||
| + | |||
| + | - Make sure the MorningLinc is in the **locked** state. Single tap the SET button on the MorningLinc to toggle between the states if it isn't currently locked. | ||
| + | - Select the '' | ||
| + | - Press the '' | ||
| + | - Press and hold the SET button on the MorningLinc module itself for 3 seconds. The Insteon address should automatically fill in to the Define and Sync dialog. If it does not, then try plugging the MorningLinc into the same outlet / circuit as the PowerLinc. | ||
| + | - Press the '' | ||
| + | - Indigo should now start the linking process. If Indigo is unable to communicate with the MorningLinc RF, then again press and hold the SET button on the MorningLinc for 3 or 4 seconds. | ||
| + | |||
| + | Next we need to re-Define and Sync the module again for the Unlocked (Turn Off) Command: | ||
| + | |||
| + | - Make sure the MorningLinc is in the **unlocked** state. Single tap the SET button on the MorningLinc to toggle between the states if it isn't currently unlocked. | ||
| + | - Press the '' | ||
| + | - Double tap the MorningLinc SET button and wait 3 seconds before the next step (the 3 second wait is important). | ||
| + | - Press and hold the MorningLinc SET button for 3 seconds. The LED should flash once and turn OFF. | ||
| + | - Press the '' | ||
| + | - Indigo should now start the linking process. If Indigo is unable to communicate with the MorningLinc RF, then repeat steps 3 to 5. | ||
| + | |||
| + | Once this is completed you should be able to both lock and unlock the device by using the **Turn On** and **Turn Off** buttons in the UI. If locking works but unlocking fails then repeat the last section of steps above. | ||
| + | |||
| + | [[http:// | ||
| + | |||
| + | [[https:// | ||