| + | ===== MorningLinc RF Controller ===== | ||
| + | The MorningLinc RF Controller has an additional INSTEON security feature which requires special linking steps. Specifically, | ||
| + | |||
| + | - Select the '' | ||
| + | - Press the '' | ||
| + | - Press and hold the SET button on the MorningLinc module itself. The INSTEON address should automatically fill in to the Define and Sync dialog. If it does not, then try plugging the MorningLinc into the same outlet / circuit as the PowerLinc. | ||
| + | - Press the '' | ||
| + | - Indigo should now start the linking process. If Indigo is unable to communicate with the MorningLinc RF, then again press and hold the SET button on the MorningLinc for 3 or 4 seconds. | ||
| + | |||
| + | That will complete the process of defining an Indigo Device for the MorningLinc. However, the MorningLinc does not appear to respond to direct Turn On and Turn Off commands from Indigo. Instead you must create individual PowerLinc links to the Morninglinc (1 for lock and 1 for unlock): | ||
| + | |||
| + | - Select '' | ||
| + | - Select an unused '' | ||
| + | - Select your MorningLinc device from the popup toward the bottom beside the word '' | ||
| + | - Single tap the MorningLinc SET button to get it into the desired lock/unlock state. | ||
| + | - Press and hold the MorningLinc SET button for 3 seconds. | ||
| + | - Press the '' | ||
| + | |||
| + | You must next repeat the steps above for the other lock/unlock state. | ||
| + | |||
| + | You'll want to select a different PowerLinc Group/Scene from the popup (step #2), and you'll want to put the MorningLinc into the opposite lock/unlock state for step #4. // | ||
| + | |||
| + | That's it. You can now use the 2 PowerLinc Scenes (or single PowerLinc Scene if you followed the modified addendum notes) to send commands to the MorningLinc to unlock and lock it. | ||